RSA Blog & Industry Insights

How Thick Are Bathroom Stall Walls? Thickness by Material

How Thick Are Bathroom Stall Walls? Thickness by Material

RSaA Restroom Stalls and All Nov 13, 2026
Tags: Bathroom Stall Thickness Options and Impact

Most bathroom stall walls are 1 inch thick. Powder coated steel, stainless steel, plastic laminate and solid plastic (HDPE) panels are usually 1 inch, and phenolic panels are usually 1/2 inch. Panel thickness drives the rest of the stall: pilasters run from 3/4 inch to 1 1/4 inch, and the hardware that fastens doors to panels has to match. Standard stall doors and panels are about 58 inches high, mounted 12 inches above the floor. For stall widths, depths and ADA stall sizes, see our restroom stall dimensions guide.

Last updated November 2026. Reviewed by Jim Southard, CEO, Restroom Stalls and All.

Thickness is one part of the layout. If the restroom includes an accessible stall, its size and grab bars follow the 2010 ADA Standards for Accessible Design. Below is the usual thickness of each partition material, what it changes in the rest of the stall, and the door heights and stall sizes that go with it.

Row of charcoal toilet partition doors, panels and pilasters installed by RSA
Panels, doors and pilasters in a row of toilet partitions installed by RSA. Photo retouched.

Bathroom stall thickness by material

Bathroom stall walls range from 1/2 inch to 1 inch. Material is the biggest factor in thickness:

Material Typical panel thickness Construction
Powder coated steel 1 in. 22 gauge galvanized steel bonded to a honeycomb core
Stainless steel 1 in. Stainless steel faces over a honeycomb core
Plastic laminate 1 in. Laminate face over a particle board core
Solid plastic (HDPE) 1 in. Solid high density polyethylene
Phenolic (black core or color thru) 1/2 in. Fiber sheets hardened with resin

Sources: manufacturer specifications for Metpar powder coated and stainless steel partitions (1 inch doors and panels, 1 1/4 inch pilasters), Scranton Products Hiny Hiders solid plastic (1 inch) and ASI Global color thru phenolic (1/2 inch panels, 3/4 inch doors and pilasters). Thickness varies by product line, so check the submittal for the line you specify.

Why does partition thickness matter? Sturdy dividers make people in your building feel safe and comfortable. Thickness also matters later, when the restroom is renovated and new partitions have to fit the existing pilaster and hardware locations. Our toilet partition materials compared guide covers price, warranty and best fit for each material.

Premium cubicles are thicker

High-privacy and European style cubicles step up from the standard 1 inch panel, with heavier doors and flush faces:

System Door and panel thickness
Bradley Euro Style (Phenolic LT) 1.4 in., with aluminum framed edges
Thrislington cubicles (Georgia projects) Doors 27 to 42 mm (about 1 1/16 to 1 5/8 in.) depending on the model, per Thrislington
Bobrick PRIVADA 1 in. high pressure laminate or wood veneer laminate

Thicker doors and panels give these systems their solid feel and let doors close flush with no sightlines. Compare the systems on our premium restroom cubicles page, or email your plans for a quote.

How thickness changes the rest of the stall

Because thickness varies by material, the rest of the stall changes with it. Pilasters run from 3/4 inch to 1 1/4 inch, and the brackets and hinges that fasten doors to panels are sized to the panel. Our team checks how your partition material affects the rest of the layout before anything is ordered.

Wood grain toilet partition doors, pilaster and panel edge with a black headrail and stainless floor shoes
Door, pilaster and panel edges on a finished stall installed by RSA. Photo retouched.

How tall are bathroom stall doors?

A standard bathroom stall door and its side panels are 58 inches high, mounted 12 inches above the finished floor, so the top of a standard stall sits about 70 inches above the floor. Privacy partitions use taller doors and panels with a smaller floor gap:

Partition type Door and panel height Gap above the floor
Standard 58 in. 12 in.
Privacy (tall) 72 in. 4 or 9 in.
Full height privacy 84 or 92 in. 4 or 9 in.

These figures come from Hadrian's phenolic partition series. Heights vary by manufacturer and product line, so check the submittal drawings for the line you specify. Why bathroom stalls have gaps explains the floor gap and how to close it.

How big is a bathroom stall?

Most standard bathroom stalls are laid out around 36 inches wide by 60 inches deep. A wheelchair accessible (handicap) stall must be at least 60 inches wide and 56 inches deep with a wall hung toilet, or 59 inches deep with a floor mounted toilet (604.8.1.1). Its door needs a clear opening of at least 32 inches (404.2.3). The restroom stall dimensions guide has diagrams for each stall type.

Price your partitions

Replacing stalls in an existing restroom: measure the room, then build your layout and get an instant quote in any material. Partitions ship nationwide, and our own crews install in Georgia, Florida, Alabama, Tennessee, South Carolina and North Carolina.

Bidding new construction: send your plans and bid date. See all commercial toilet partitions, or call 1-844-81-STALL.

10,000+ projects completed. BBB accredited, A+ rating. Our own W2, background-checked installation crews, licensed and insured.

Requirements on this page summarize the 2010 ADA Standards for Accessible Design (U.S. Department of Justice). Many states and cities enforce accessibility through their building code, which may adopt ICC A117.1 or local amendments that differ from the federal standard. Confirm requirements with your architect or local building official before ordering or installing.